NEW TDW THREAD-O-RING™ FITTING
The NEW 3-WAY THREAD-O-RING ™ is the same great TDW fitting with an added outline for welded branch connections. Get the fittings you need when you need them.
get the fittings you need when you need them
The NEW 3-WAY THREAD-O-RING™ is the same great TDW fitting with an added outlet for welded branch connections. The fittings are available in 1-inch; 1 1/4-inch and 2-inch sizes.
Pipe type: carbon steel, stainless steel, aluminum
1480 pressure rated
Compatible with existing TDW equipment
Best in market lead times in the industry
Kerr Engineered Sales Company has been representing leading pipeline repair and performance companies in Eastern US since the company was founded in 1952. Seventy two years later, the company remains a family business serving customers with the highest quality service and expertise.
Our application specialists at Kerr Engineered Sales Company are also available for demonstrations, team presentations, lunch and learns and customer visits.
TROUBLESHOOTING PIG-SIG V
PIG-SIGs detect pigs, spheres, scrapers, and other tools as they pass distinct points along the pipeline. They can also alert operators if a pig is lost or stuck. This blog has tips and solutions to the most common issues with the TDW Pig Sig V.
Tips, solutions and operating guide for issues with TDW Pig-Sig V.
Pig passage indicators are commonly referred to as “PIG-SIGs,” a term TDW originated more than 60 years ago. They accurately detect pigs, spheres, scrapers, and other tools as they pass distinct points along the pipeline and when they reach the receiver, and can also alert operators if a pig is lost or stuck.
The weatherproof and corrosion-resistant PIG-SIG® V pig passage indicator is built to withstand most environments. All components exposed to pipeline products are completely sealed to prevent leaks.
NOTE: It is very important to read these troubleshooting guidelines in conjunction with the Pig Sig V Operating and Maintenance instructions PIG- SIG V Guide
ISSUE: The Plug assembly won’t thread on to the THREAD-O-RING ™ Nipple
Verify that it is indeed a TDW THREAD-O-RING. The hole in the pipe may be too small or not centered. The TDW THREAD-O-RING may be swedged due to over-tightening of a valve or cap. Measure the inside dimension (ID) to ensure it is not swedged or egged.
ISSUE: PIG-SIG V has never worked correctly
Verify that the proper TDW THREAD-O-RING was used to correspond with the wall thickness of the pipe. Measure the height of the THREAD-O-RING as it is mounted to the pipe and then add that measurement to the wall thickness of the pipe. The measurement should not exceed 4.50 inches but needs to be greater than 4.25 inches.
ISSUE: The Plug stopped working correctly
If the plug is contaminated, install a new filter pack version. If there is wax build up in the plug: consult with the TDW factory regarding other plug options.
If The Trigger is damaged, the first step is to verify that the proper TDW THREAD-O-RING was used for corresponding wall thickness of pipe. Measure the height of the TDW THREADO-RING as it is mounted to the pipe and then add that measurement to the wall thickness of the pipe. This measurement should not exceed 4.50 inches but needs to be greater than 4.25 inches.
The plug may have wax or other buildup that is preventing the trigger from moving. This can lead to the plug being damaged.
ISSUE Electrical or Combo Electrical switch is not sending electrical signal
Check for the proper switch adjustment. Please refer to electrical switch instruction in the manual and ensure that the switch is adjusted properly.
Ensure that the double torsion spring is still installed correctly.
Verify that the indicator is properly installed. Check the indicator installation by removing a set screw and looking for the groove on the plug.
Verify that the plug is fully installed. Measure the distance the plug extends above the THREAD-O-RING Nipple; the distance should be 1 3/8 inches.
In the event of freezing weather, the seal on the indicator may have been compromised allowing water to enter the upper position of the plug. This water can freeze and not allow the magnet to move.
ISSUE: Indicator - The All Types Flag doesn’t raise after assumed pig passage
Verify that the indicator is properly installed: check indicator installation by removing a set screw and looking for the groove on the plug.
Verify that the plug is fully installed: Measure the distance the plug extends above the THREAD-O-RING nipple (should be 1-3/8 inches).
In the event of freezing weather: the seal on the indicator may have been compromised allowing water to enter the upper portion of the plug. This water can freeze and not allow the magnet to move. Remove indicator and check for moisture.
IN THE EVENT OF FREEZING WEATHER:
Remove indicator to check for moisture. 65 Section VII – Maintenance Table 11. PIG-SIG V Maintenance Intervals Item Interval Seal Inspect every six months for tears or cracks.
Replace annually (order seal kit).
Magnet Inspect annually.
Replace if cracks or chips are present.
Indicator O-ring is recommended to be replaced annually.
Plug O-ring Inspect any time the plug is removed. Replace annually.
Plug Backup Ring should be replaced each time the plug is removed.
NOTE: Times may vary depending on the pipeline product and the environment that the unit is exposed to.
ISSUE:Flag does not raise after assumed pig passage/switch does not actuate or release (reset)
Proper switch adjustment: refer to electrical switch instruction in the manual and ensure the switch is adjusted properly. The gap between polymer slider and switch plunger should be between 0.005 and 0.02 inches (0.1 to 0.6mm).
To discuss issues with your Pig Sig V please contact any of the KERR team.
Kerr Engineered Sales Company has been representing leading pipeline repair and performance companies in Eastern US since the company was founded in 1952. Seventy years later, the company is still a family run business serving customers with the highest quality service and support.
GPT EVOLUTION INSTALL USES ZEVAC
A gas operator installing an 8in GPT EVOLUTION isolation gasket utilized ZEVAC to capture and recover vented gas. This made the operation emission free.
Gas operator installing 8 in GPT eVolution gasket UTILIZes ZEVAC TO MAKE THE OPERATION EMISSION free
Isolation gaskets are installed to protect lines from corrosion and unintentional leaks. Inmost cases, installing these gaskets requires sections of pipelines to be evacuated and purged, often by gas venting. The practice of venting creates intentional natural gas emissions, releasing methane into the atmosphere. It is a paradox to vent while protecting against leaks.
A gas pipeline operator in Pennsylvania needed to install an 8in GPT Evolution Isolation gasket at a well pad north of Pittsburgh. Instead of venting before installing and releasing emissions into the environment, they utilized ZEVAC services to capture and recover the vented gas. To draw down 200ft of 8in line from approximately 200 psi down to zero with ZEVAC took approximately one hour from set up to the point when the gas in the section had been re-compressed into an adjacent line.
Company personnel were then able to install the GPT EVOLUTION gasket. This gasket is fully encapsulated and just 1/8in thick for easy installation. The GPT EVOLUTION is extremely abrasion and impact resistant due to the proprietary coating. It is also fire safe and does not have lamination.
This project protected their pipeline and protected the environment.
For more information on GPT, ZEVAC or any of the manufacturers Kerr represents, please contact Kerr Engineered Sales Company.
Application specialists are available for team presentations, lunch and learns and customer visits.
TDW Pig Parts - A Guide
TDW Pigs have various components. They come in a multitude of configurations. This blog reviews key parts that you’ll find on pigs and explains some of their uses.
TDW PIGGING INSIGHTS - Episode 4
Overview of TDW Pig Parts and Their Uses
TDW Pig Parts
TDW designs and manufactures an extensive selection of pipeline pigs for specific applications, such as liquids displacement, cleaning, batching, gauging.
Pigs have various components, and each pig comes in a multitude of configurations. This blog looks at some of the key parts that make up a pig and explains the uses of these parts.
pig PArts and their uses
Discs: Are effective at pushing out solids and providing a good support for the pig.
Conical Cups: Provide excellent sealing characteristics, good support and long wear.
Bypass Ports: These allow some of the flow to bypass through the pig and help minimize solid build up at the front of the pig.
Spring Mounted Brushes: Provide a continuous forceful scraping for removal of rust, scale and other build ups on the wall of the pipe.
Circular Brushes: The brushes are bi-directional and can be stacked for scraping for removal of rust, scale and build-ups.
Pit Boss/Pencil Brush: Scrapes deep into pits to remove build-ups.
Gauge Plate: For discovery of deformities/obstructions in the line, also commonly used prior to ILI runs.
Magnets: Pick up ferrous materials and give indications to loose debris in the line.
Learn more about TDW Pigs and Resources
TDW Pig Resource page.
If you have questions, please contact the Kerr Engineered Sales Company who are also available for team presentations, lunch and learns and customer visits.